Communication & monitoring |
Communication interfaces |
MasterBus, CZone, NMEA 2000 |
|
General specifications |
MasterBus powering |
yes, incl. Smart MasterBus Powering (switched off for CZone or NMEA 2000 communication) |
Battery voltage |
12 and 24 V DC, 36 and 48 V DC is supported from MasterShunt 500 device hardware version K. |
Current |
300 A continuously, 400 A for 10 min., 500 A for 5 min. and 600 A for 2 min. |
Main fuse |
bus bar included in MasterShunt, Class T fuse or ANL fuse to be ordered separately |
Idle consumption |
23 mA (normal operation), <1 mA (power saving, MasterBus off) |
System functionality |
alarms, timers, auto start/stop for generator |
System information |
e.g. time remaining, voltage, current, state of charge |
Programmable alarms |
warning low voltage, low state of charge, high voltage |
Dimensions, hxwxd |
150 x 150 x 65 mm
5.9 x 5.9 x 2.6 inch |
Weight |
0.7 kg
1.5 lb |
Delivered with |
MasterShunt, temperatuursensor, MasterBus terminator, isolatiekap voor DC aansluitingen, 1 mtr Mastervolt-CZone dropkabel |
|
Technical specifications |
Battery types |
Gel, AGM, flooded, Lithium Ion |
Protection degree |
IP21 |